Tankless Water Heater Leaking in Duluth, GA: Supply, Valve, or Condensate?
Water at a tankless water heater in Duluth, GA can come from the supply connections, the pressure relief valve, or the condensate drain. The meter test tells them apart: a supply leak moves the meter with every tap off, while condensate water appears only while the unit runs.
Three sources at one unit
Water at a tankless water heater can come from three places, and the puddle on the floor alone cannot tell you which one it is. The first is the supply connections: the hot and cold lines into and out of the unit, under pressure whenever the water is on. The second is the pressure relief valve: the valve that discharges water when pressure or temperature inside the unit rises. The third is the condensate drain: on a condensing model, the small line that carries away the water the unit produces from its exhaust gases while it runs.
The three sources behave differently, and that is what separates them. A supply leak runs whether the unit is running or not, because the connections are under pressure all the time, and the water keeps coming. A relief valve discharge follows pressure or temperature, so it appears when the unit is working hard and stops when it cools. Condensate water appears only while the unit runs, because a condensing model only produces it while it is heating. Our water heater guide covers the tank type, where a tank, a drain valve, and the same relief valve are the suspects, and the tankless unit is the same search without the tank.
Timing is the first clue
When the water appears is the most useful clue a homeowner has, and it costs nothing to note. A supply leak keeps the floor wet all the time, and the puddle grows while no tap runs, because the connections are under pressure whether the unit runs or not. A relief valve discharge appears after the unit has been working, and the floor dries between uses, because the valve only opens when pressure or temperature rises. Condensate water appears only while the unit runs, and stops when it is off, because the unit only produces it while heating.
Watch the floor for a day and write down what you see. Note whether the water is there in the morning after a night with no hot water use, whether it appears only after showers or laundry, and where exactly it is: at the connections points to the supply, at the relief valve discharge pipe points to the valve, and at the condensate drain points to the drain. That note is the first thing the visit asks for, because it already separates the most likely sources before any check is run. Our low water pressure guide uses the same timing test where a leak is only one possible cause, and the meter test is the check that separates it from the others.
| When it appears | What it may mean |
|---|---|
| All the time, growing while no tap runs | A supply leak at the connections |
| Only while the unit runs | Condensate water from the drain |
| After the unit has been working hard | A relief valve discharge |
| At the relief valve discharge pipe | The relief valve opening |
| At the condensate drain line | A blocked or disconnected drain |
| Meter moves with every tap off | Metered supply water is escaping somewhere |
| Meter still, water only while it runs | Condensate water, not a supply leak |
The meter test, with the unit isolated
Run the meter test before anything else. Turn every tap off, read the meter, wait without using water, then read it again. If the meter moved, supply water is escaping somewhere, which fits a leak at the connections or the relief valve. If it did not move, the water is not coming through the metered supply while the test ran, which fits condensate water. The U.S. EPA's WaterSense program publishes the same household meter-test guidance on its Fix a Leak Week page, and our guide to checking your water meter for a leak walks through the reading step by step.
Then watch whether the unit fires. A tankless unit heats water when water flows through it, so if it fires with every tap closed, water is moving through it somewhere. A leak downstream is one reason water keeps moving, and the meter test is the check that confirms it. That pair of results — the unit firing with nothing running and the meter moving with every tap off — moves the whole search from the unit to the pipes beyond it, or from the pipes to the unit, and it is the reason both are noted before any other check is chosen. Our underground guide covers the same meter test for the buried line, where the water also moves with nothing running.
One caution: a supply leak can be slow, and a slow leak can be quiet on a single meter test, so a still meter does not by itself clear the connections if the floor keeps getting wet. If the puddle keeps growing with the meter still, say so on the call, and the visit re-checks with the timing noted rather than treating one still reading as the final answer. Never cap, plug, or block a relief valve: it is a safety device, and blocking it can turn a drip into a hazard.
What does detection check for a tankless water heater leak, and what can it not do?
On the supply side, the visit narrows the leak with acoustic listening on the connections, moisture readings on the floor and the wall around the unit, and pressure testing on the lines, and marks the point the checks agree on.
The visit needs access around the unit, so clear the area before the visit if you can, and say on the call whether the shutoff valves on the lines are reachable. Detection does not repair a connection, replace a valve, or service the unit: the repair is a plumber's job for the lines and the valve, and the unit itself is a technician's job. What detection does is prove which side of the shutoff the water is on, so the right trade is called with a marked point rather than with a wet floor and a guess.
When the wall or floor around the unit is wet
A wet wall or floor around a tankless unit means water has been reaching it for some time, and the wall itself is now part of the problem. Drywall softens when it stays wet, and a soft patch can hide how much water has spread behind the unit.
If water is spreading, close the shutoff valves on the lines if it is safe to reach them, and call with the facts first — where the water is, when it appears, and what the meter did with every tap off. The wet wall is a repair question, not a detection finding. Detection marks the supply side first, and the plumber decides what the wall and the unit need once the area is open and the damage can be seen.
What should I tell you about a tankless water heater leak when I call?
Say when the water appears: all the time, only while the unit runs, or only after it has been working hard. Say where exactly the water is — at the connections, at the relief valve discharge pipe, or at the condensate drain — and whether the wall or floor feels wet or soft.
A tankless water heater leak is a small search with a clear method: timing first, then the meter test, then the checks on the side the test points to. The wet floor alone cannot tell you whether the water is the supply connections, the relief valve, or the condensate drain, but the three checks together usually can, without opening anything to find out. That is the whole point of detection beside a unit: find which side of the shutoff the water is on before anyone opens anything to fix it.

Common questions
Can a tankless water heater leak raise the water bill?
Yes, if the leak is on the supply side. The connections and the relief valve carry metered water, so a leak at either one loses water whether a tap is running or not. Condensate water is different: it comes from the exhaust gases of a condensing model, not from the water supply, so it does not raise the bill. Run the meter test with every tap off: a moving meter points to supply water.
My tankless unit keeps firing with nothing running — is that a leak?
It can be a sign of one. A tankless unit heats water when water flows through it, so if it fires with every tap closed, water is moving through it somewhere. A leak downstream is one reason water keeps moving, and the meter test is the check that confirms it. Turn every tap off, read the meter, wait without using water, then read it again, and say what it did on the call.
Water appears only while the unit runs — is that a leak?
It can be condensate, not a supply leak. A condensing tankless model produces condensate water while it runs, and that water drains away through a small line. If the drain is blocked or disconnected, the water shows at the unit only while it runs. A supply leak is different: it runs whether the unit is running or not. Note whether the water follows run time, and say so on the call.
Where does condensate water come from?
Condensate comes from the exhaust gases of a condensing tankless model. The unit extracts heat from the gases as they leave, and the moisture in them condenses into water, which drains away through a small line. That water is not supply water, so it does not move the meter or raise the bill. If the drain line is blocked or disconnected, the water shows at the unit instead of draining away.
What if the relief valve on my tankless unit is dripping?
A relief valve can discharge when pressure or temperature inside the unit rises, so an occasional discharge is not the same as a steady drip. A valve that drips steadily is worth the meter test, because the water it discharges is metered supply water. Never cap, plug, or block a relief valve: it is a safety device, and blocking it can turn a drip into a hazard. Say what the valve is doing on the call.
What if the meter is still but water keeps appearing at the unit?
Then the water is not coming through the metered supply while the test ran, which points to condensate or to a drain problem. Note whether the water appears only while the unit runs, and whether it stops when the unit is off. A unit that keeps getting wet with a still meter is worth a look with the timing noted, because a slow supply leak can be quiet on a test, and the visit re-checks rather than guessing.